Caruna’s avoided emissions and carbon handprint
Caruna plays a key role in the electrification of Finland. The company connects renewable energy generation to the electricity grid and strengthens the grid to enable electrification across different sectors, such as transport, industry, and heating. Through these actions, Caruna contributes to avoided emissions that support society’s transition towards carbon neutrality.
Caruna influences avoided emissions indirectly, and these avoided emissions are not solely the result of Caruna’s operations.
What are avoided emissions?
Avoided emissions describe greenhouse gas emissions that are avoided in customers’ activities as a result of solutions or activities enabled by a company. They are also sometimes referred to as a carbon handprint. While a carbon footprint focuses on a company’s own emissions, avoided emissions reflect the positive climate impact enabled by the company.
In other words, avoided emissions indicate how much a company’s solutions help others reduce their carbon footprints.
In addition to reducing emissions from its own operations and value chain, Caruna aims to enable emissions reductions for its customers and society. As an electricity distribution company, Caruna enables avoided emissions by connecting renewable energy generation to the electricity grid and strengthening the grid to support the electrification of society. Avoided emissions arise from the combined impact of multiple actors and are therefore not attributable to Caruna alone.
Determining avoided emissions
The determination of avoided emissions has been carried out in accordance with the Methodology for the assessment and calculation of avoided emissions in electricity distribution (Halkilahti, 2025). The method is based on the Carbon Handprint Guide developed by VTT Technical Research Centre of Finland and LUT University, as well as the Guidance on Avoided Emissions by the World Business Council for Sustainable Development (WBCSD), and it applies a life cycle assessment (LCA) approach.
More information about the methodology is available in Finnish here.
Steps in the methodology for assessing avoided emissions in electricity distribution
1. Selection of impact pathways
1. Selection of impact pathways
Avoided emissions in electricity distribution arise from different impact pathways, for example when renewable energy generation is connected to the electricity grid and when grids are strengthened to enable electrification across various sectors. At this stage, the impact pathways included in the assessment are defined.
Impact pathways
Caruna has assessed avoided emissions for two impact pathways: the electrification of transport and the electrification of heating. For other impact pathways, the determination is ongoing.
1.1 Electrification of transport
The electrification of transport generates avoided emissions when fossil fuels are replaced by electricity generated predominantly from non-fossil energy sources. Caruna enables the electrification of transport by strengthening its electricity grids to ensure sufficient capacity to meet the growing power demand resulting from charging stations and home charging.
The assessment is limited to passenger cars, vans, trucks, and buses within Caruna’s grid area, based on the municipalities where the vehicles are registered.
1.2 Electrification of heating
The electrification of heating generates avoided emissions when fossil energy sources are replaced with electricity produced largely without fossil fuels. Electrification of heating can take place through the electrification of district heating, for example via electric boilers, or through the electrification of individual heating systems, such as heat pumps. Caruna enables the electrification of heating by strengthening its electricity grids and establishing new connections to ensure sufficient grid capacity to meet the growing demand for power.
The assessment of avoided emissions is limited to the electrification of district heating production within Caruna’s grid area. Avoided emissions related to individual heating systems are not included in the assessment.
2. Eligibility assessment
2. Eligibility assessment
The eligibility of the company and the selected impact pathways is assessed through a three-step process to prevent the methodology from being used to support misleading claims.
Caruna and the impact pathways assessed meet all three eligibility criteria defined in the methodology
In the first phase of the eligibility assessment, the company’s eligibility is evaluated. Caruna has climate targets covering GHG Protocol Scopes 1–3 and reports progress against them regularly. Caruna therefore meets the Gate 1 criteria. The subsequent phases of the eligibility assessment examine the eligibility of the impact pathways. The impact pathways assessed have the potential to mitigate climate change, and Caruna plays a role in enabling their advancement. The eligibility criteria for the impact pathways are also met.
3. Defining the assessment period
3. Defining the assessment period
The calculation of avoided emissions is carried out either as an annual assessment or as a future scenario-based assessment.
Assessment periods
The determination of avoided emissions is carried out both as an annual assessment and as a scenario-based assessment. In the annual assessment, avoided emissions are determined for historical years based on statistical data. In the scenario-based assessment, avoided emissions are calculated for the future based on electrification scenarios. Actual avoided emissions may differ if the scenario does not materialize as assumed. The purpose of the scenario-based assessment is to illustrate the potential scale of avoided emissions enabled by electrification and the grid investments required to support it.
4. Defining the reference scenario
4. Defining the reference scenario
Avoided emissions are assessed against a reference scenario representing the continuation of the current situation, or business as usual.
Reference scenario
Avoided emissions are always determined relative to a reference. The reference scenario aims to describe what emissions would have been if no change, such as the electrification of transport or heating, had taken place. The reference scenario used is the continuation of the current situation (business-as-usual, or BAU scenario). The reference scenario therefore represents the emissions that would occur if the situation of the previous year, or a historical year defined in the scenario-based assessment, were to continue into the assessment year.
5. Reviewing life cycle assessment requirements
5. Reviewing life cycle assessment requirements
In the calculation of avoided emissions, the functional unit, system boundaries, and the required data and its sources are described in accordance with life cycle assessment (LCA) requirements.
Life cycle assessment requirements
5.1 Electrification of transport – impact pathway
In the assessment of the electrification of transport impact pathway, the functional unit used is one vehicle-kilometre. The results have been scaled to Caruna’s grid area based on the number of vehicles and average vehicle kilometres travelled. Within the system boundaries of the assessment, the electricity distribution system is included within the system boundary, meaning the construction of electricity grid infrastructure and the emissions from its materials, as well as the vehicle use phase. The required data were mainly sourced from statistical data provided by Traficom and Statistics Finland. In addition, Caruna’s own emissions calculation data were used to account for emissions related to electricity grid infrastructure.
5.2 District heating electrification impact pathway
In the assessment of the electrification of district heating impact pathway, the functional unit used is 1 GWh of district heat. The results have been scaled to Caruna’s grid area based on the amount of district heat produced. The electricity distribution product system is included within the system boundaries of the assessment, meaning the construction of electricity grid infrastructure and the emissions from its materials, as well as the use phase of district heating. The required data were mainly sourced from district heating statistics collected by Energy Industry Finland (Energiateollisuus ry). In addition, Caruna’s own emissions calculation data were used to account for emissions related to electricity grid infrastructure.
6. Assessing the quality of the data used
6. Assessing the quality of the data used
The reliability of the data sources used is evaluated using three categories to enable assessment of the result’s credibility.
Data quality
6.1 Electrification of transport – impact pathway
The statistical data used in the assessment of the electrification of transport impact pathway are published by public authorities and are up to date, as well as representative of Finland at the regional level. Some estimates are required when national-level statistics are allocated to Caruna’s grid area. These estimations have been evaluated under the yellow data quality category. In the scenario-based calculations, a nationwide traffic forecast published by Traficom is used, along with the company’s own forecast for the development of the number of electric vehicles in the area. Actual figures may differ if the forecasts do not materialize as assumed.
Emissions related to electricity grid infrastructure are based on the company’s emissions calculations. Allocating the share attributable specifically to the impact pathway under assessment is challenging, as grid infrastructure is not used for a single purpose and its use is not disaggregated. Due to these allocation challenges, emissions from electricity grid infrastructure are deducted in full from the combined avoided emissions calculated for the different impact pathways.
Based on the data quality assessment, the calculation uses the most accurate data currently available. Remaining uncertainties relate primarily to assumptions, allocation choices and the realisation of future scenarios.
6.2 District heating electrification impact pathway
The data used in the assessment of the electrification of district heating impact pathway are based on district heating statistics and emissions calculation tools compiled by Energy Industry Finland (Energiateollisuus ry), with data available at the level of individual district heating companies. In the scenario-based calculations, company-specific forecasts from the same sources are used. Actual figures may differ if the forecasts do not materialize as assumed.
Emissions related to electricity grid infrastructure are based on the company’s emissions calculations. Allocating the share attributable specifically to the impact pathway under assessment is challenging, as grid infrastructure is not used for a single purpose and its use is not disaggregated. Due to these allocation challenges, emissions from electricity grid infrastructure are deducted in full from the combined avoided emissions calculated for the different impact pathways.
Based on the data quality assessment, the calculation uses the most accurate data currently available. Remaining uncertainties relate primarily to assumptions, allocation choices and the realisation of future scenarios.
7. Calculation of avoided emissions
7. Calculation of avoided emissions
Avoided emissions are calculated as the difference between emissions in the assessment year and the reference scenario, taking into account the emissions from grid infrastructure required to enable the change.
Calculation of avoided emissions
Avoided emissions are calculated using the methodology described at the beginning of Section 2. Avoided emissions are calculated as the difference between emissions in the assessment year and the reference scenario, taking into account the emissions from electricity grid infrastructure required to enable the change.